CtrlK
BlogDocsLog inGet started
Tessl Logo
SkillPublic

mdr-745-specialist

EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, Art. 86 PSUR schedules, and EUDAMED integration. Use when classifying a medical device under MDR, building or gap-checking a technical file, planning clinical evaluation or PMS/PSUR cadence, or preparing for notified body review (e.g., 'what class is my device under MDR', 'review my PSUR schedule').

72

Quality

91%

Does it follow best practices?

Run evals on this skill

Adds up to 20 points to the overall score

View guide
SecuritybySnyk

Passed

No findings from the security scan

SKILL.md
Quality
Evals
Security

Quality

Content

82%Weight 40%Scale 1-5

Reviews the quality of instructions and guidance provided to agents. Good implementation is clear, handles edge cases, and produces reliable results.

A well-structured regulatory skill: every workflow is numbered with a validation step, quick-reference tables carry the MDR facts Claude needs, and detail is correctly pushed to three real one-level-deep reference files with a usable script. Weaknesses are modest: some generic advisory padding, no error-recovery loops around the validation checkpoints, and a TOC/navigation gap for the final section.

Suggestions

Trim the generic 'Notified Body Interface' selection-criteria table and the 'Risk' row of the classification matrix — both are padding relative to the MDR-specific content surrounding them; move any needed Notified Body detail into technical-documentation-templates.md.

Add error-recovery guidance to the validation checkpoints, e.g., 'if the gap analyzer reports critical gaps, remediate documentation before NB submission' or 'if rules conflict, apply the higher-classification rule (Annex VIII, last indent) and document the rationale'.

Add 'Notified Body Interface' to the Table of Contents so every section is navigable, and consider relocating 'Qualified Evaluator Requirements' to clinical-evidence-requirements.md.

DimensionReasoningScore

Conciseness

Mostly dense, MDR-specific facts (PSUR frequencies, vigilance timelines, conformity routes) that Claude cannot be assumed to know, but there are trimmable padded passages: the generic 'Notified Body Interface' advisory table ('Designation scope', 'Capacity', 'Fee structure') and the simplistic 'Risk: Lowest/Low-medium/Medium-high/Highest' row of the classification matrix add little regulatory value. Anchor 4 ('minor instances of over-explanation that could be trimmed') fits better than 5, and it is well above the 3 anchor's 'unnecessary explanation'.

4 / 5

Actionability

Guidance is fully executable: copy-paste-ready script invocations ('python scripts/mdr_gap_analyzer.py --device "Device Name" --class IIa --output json'), worked classification examples with definite outcomes (suture → Rule 8 → Class IIb), and concrete lookup tables (PSUR schedule, incident reporting timelines of 2/10/15 days) covering the common cases. This matches the top anchor rather than level 4's 'minor gaps'.

5 / 5

Workflow Clarity

All five workflows are clearly numbered with an explicit bolded '**Validation:**' checkpoint (e.g., 'Classification confirmed with Notified Body', 'PMS system audited annually') plus checklists (GSPR matrix, UDI label, pre-submission). However, validations are single checkpoints with no error-recovery feedback loops (what to do when the gap analyzer flags critical gaps or the NB challenges the rationale), which is exactly the gap between anchor 4 and anchor 5; the sequence quality keeps it clearly above 3.

4 / 5

Progressive Disclosure

Good structure overall: three real, one-level-deep reference files each summarized with a content bullet list, a working script, and a TOC. Minor organization gaps keep it at anchor 4 rather than 5: the 'Notified Body Interface' section is missing from the Table of Contents, and its advisory detail (plus 'Qualified Evaluator Requirements') arguably belongs in a reference file rather than the overview body.

4 / 5

Total

17

/

20

Passed

Description

100%Weight 40%Scale 1-5

Based on the skill's description, can an agent find and select it at the right time? Clear, specific descriptions lead to better discovery.

A model description: concrete capabilities anchored to specific MDR articles and annexes, explicit 'Use when' triggers with example user queries, and a tightly scoped EU MDR niche that minimizes conflict risk. Third-person voice and every clause earns its tokens.

DimensionReasoningScore

Specificity

The description lists multiple concrete capabilities — 'medical device classification, technical documentation, clinical evidence, and post-market surveillance' — and grounds them in specific regulatory artifacts ('Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, Art. 86 PSUR schedules, and EUDAMED integration'). This matches the top anchor's comprehensive, multi-action coverage; there is no vagueness to push it to 4.

5 / 5

Completeness

Both questions are explicitly answered: what — 'compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance' — and when — 'Use when classifying a medical device under MDR, building or gap-checking a technical file, planning clinical evaluation or PMS/PSUR cadence, or preparing for notified body review' with concrete example queries. This is the anchor-5 pattern verbatim in structure.

5 / 5

Trigger Term Quality

Natural trigger terms are comprehensive with synonyms: 'EU MDR 2017/745', 'medical device classification', 'technical file', 'clinical evaluation', 'PMS/PSUR', 'notified body', plus literal user phrasings ('what class is my device under MDR', 'review my PSUR schedule'). Coverage includes both abbreviation and spelled-out variants, matching the comprehensive top anchor rather than the 'a few natural terms missing' level 4.

5 / 5

Distinctiveness Conflict Risk

The niche is tightly scoped to 'EU MDR 2017/745' with regulation-specific triggers (Annex VIII, PSUR, EUDAMED, notified body), so it would not fire for generic document, coding, or other regulatory-framework skills. Clear niche with distinct triggers, matching the top anchor.

5 / 5

Total

20

/

20

Passed

Validation

87%

Checks the skill against the spec for correct structure and formatting. All validation checks must pass before discovery and implementation can be scored.

Validation — 14 / 16 Passed

Validation for skill structure

CriteriaDescriptionResult

metadata_version

'metadata.version' is missing

Warning

metadata_field

'metadata' should map string keys to string values

Warning

Total

14

/

16

Passed

Repository

alirezarezvani/claude-skills

Path

ra-qm-team/skills/mdr-745-specialist/SKILL.md

Reviewed

Table of Contents

Is this your skill?

If you maintain this skill, you can claim it as your own. Once claimed, you can manage eval scenarios, bundle related skills, attach documentation or rules, and ensure cross-agent compatibility.