CtrlK
BlogDocsLog inGet started
Tessl Logo

jbaruch/hubitat-dev

Context for developing and debugging Hubitat Elevation apps, drivers, and hub environment — sandbox constraints, lifecycle idioms, capability contracts, plus grounded deploy/log-tail/lint mechanisms.

Quality

Does it follow best practices?

Run evals on this skill

Adds up to 20 points to the overall score

View guide

SecuritybySnyk

High

Do not use without reviewing

Overview
Quality
Evals
Security
Files

firmware-update.mdrules/

alwaysApply:
Yes
description:
Z-Wave device firmware (OTA) updates on Hubitat — a failed OR stalled flash can hang the whole controller; prerequisites, vendor-latest sourcing, and the mandatory watchdog/canary/RSSI-floor guardrails

Z-Wave Firmware Updates

Updating device firmware is one of the few genuinely dangerous operations on a hub: a bad flash is closer to a brick than a git revert, and — the trap that surprised us — a flash that merely stalls can take the whole radio down with it. Flash deliberately, one radio at a time, guarded.

Use the hub's native zwaveJS updater, not a driver swap

  • Settings → Z-Wave Details → Maintenance → Device firmware updater (UI page /hub/zwaveInfo) flashes OTA over the radio the device already uses. It handles Long Range + S2; the community driver-swap updaters (swap to a firmware-updater driver, call updateFirmware(url)) stall on LR/S2 ("Please wake up your sleepy device" on a mains device = wrong tool, not "wait longer").
  • HTTP surface (no auth, Hub Security off): POST /hub/fileManager/upload/firmware (multipart), GET /hub/zwave/deviceFirmware/files, GET …/details?nodeId=N, POST …/start {nodeId,target:0,fileName}, GET …/progress?nodeId=N{progress:{percent,stage}} (PROCESSSENDINGDONE). It flashes in place — no driver change, the device keeps its real driver. skills/_scripts/hub_fw_update.py drives it; skills/firmware-update/SKILL.md is the procedure.

Prerequisites (check before flashing)

  • Backend is zwaveJS (zwaveJS:true in /hub/zwaveDetails/json). This skill/API is the zwaveJS updater.
  • Right image for the hardware revision. 700-series and 800LR share a model name but need different files — pick by the installed major version (ZEN76 3.x → 3.60 / 800LR; 2.x/10.x → 700-series). The wrong image bricks; the hub rejects a mismatch at /start, but do not rely on that.
  • Mains vs battery/FLiRS. Mains devices flash unattended. Battery/sleepy devices (locks, most sensors) must be awake for the multi-minute transfer — USB power, fresh batteries, or operate them to wake (a lock via lock/unlock, a motion sensor via motion). A lock also has a second firmware plane (main/Wi-Fi over Bluetooth in the vendor app) distinct from the Z-Wave module image the hub flashes.
  • One batch per radio. A hub's Z-Wave is single-threaded for OTA — never run two flashes into the same radio at once; chain them (--wait-pid) or run different hubs in parallel.

Source vendor-latest — NOT the hub's auto-discovery

  • GET /hub/zwave/deviceFirmware/available?nodeId=N (the Z-Wave JS firmware service) lags and mis-matches: it offered ZEN04 2.30 when the vendor shipped 2.60 (missing the 2.40 redundant-report fix and the 2.50 SDK 7.19→7.24 S2/SPAN fix), and it offered a Springs shade a bogus downgrade to "1.5". Use it only as a rough "is there anything", never as the version/file.
  • Get the real latest from the vendor, and read the change log to justify the update: Zooz — free at getzooz.com/firmware/<MODEL>_V<MM>R<mm>.zip (.gbl 700/800, .otz 500); Leviton — free .ota on leviton.com/content/dam/leviton/support/ (never cross model files); Ultraloq — free .gbl on file.u-tec.com. Some vendors publish no downloadable firmware (Springs/Somfy shades refuse "old motor" updates and aren't in the service) — then there is nothing to do; say so.
  • Newer is not always better: verify the change log addresses the problem, and heed community reports (Ultraloq 1.5 on 1.01 units often fails outright and can worsen lock-state reporting with no downgrade path; a Springs 13.3 motor is reported more reliable than 14.7).

The load-bearing hazard: a failed OR stalled OTA hangs the whole controller

Grounded live twice (2026-07-22). A flash that fails mid-transfer, or stalls (percent freezes and never emits DONE/FAILED), hangs the entire zwaveJS controller — not just that node:

  • The hub keeps returning success:true to every command but transmits nothing; every Z-Wave node freezes at once.
  • Zigbee is unaffected — Zigbee sensors keep reporting. That asymmetry is the diagnostic tell: it's the Z-Wave controller, not the mesh, not the device.
  • The Hub-Mesh peer still shows active/reachable — invisible to the peer table (same class as zwave-zigbee-mesh.md's "peer looks fine but drops commands"). Even a local command on the owning hub returns success but never reaches the node (its lastTime doesn't advance).
  • Downstream blast radius: frozen sensors go stale, which staleness-poisons every lux/temperature-gated automation — a "Motion at Dark" rule fired lights in daylight because the illuminance sensor's radio was hung at last night's value. A hung radio is not just frozen devices.

Why a big fleet hides it and a small one doesn't: on a hub with many devices to flash, successes after a failure keep re-kicking the radio so a transient hang self-clears; on a hub with few devices, or when the last/only flash fails, nothing follows to shake it loose and the radio stays wedged silently. The trailing/only failure is the dangerous one.

Guardrails (all required — one alone is not enough)

  1. No-progress watchdog. Abort a flash if percent stops advancing for a few minutes at ANY level, not only at 0%. A frozen transfer never emits DONE/FAILED, so a plain start→wait-for-DONE loop hangs forever and takes the radio with it. (A canary-only guard missed a mid-transfer stall — that's why this is separate.)
  2. Canary radio-health probe, run only after a failed flash. A hung controller freezes every node's lastTime (it transmits nothing); a healthy hub always has some node reporting, and a rebooting hub advances lastTimes as it re-interviews. So nudge a known-healthy mains node and, over a wide window, check whether ANY node's lastTime advances — not whether one specific node answers inside a tight window. If nothing advances, the controller is hung → reboot and re-check; abort if it stays hung. Two false-positive traps this avoids, both learned live on a 75-LR-node hub: (a) do not probe after a successful flash — the success already proved the radio transmits, and the flashed device's own re-interview busies the radio → needless reboot; (b) a single-node/30 s check false-reads "hung" (and post-reboot "still hung," while zwaveJS is still interviewing) even though the radio is fine — checking any node over a wide window fixes both directions.
  3. RSSI floor. Skip nodes at/below ~−95 dBm lwrRssi (SiLabs RX floor: −97 dBm 700-series, −110 dBm 800-LR) — floor-signal nodes are hang-prone and rarely flash. Not worth risking a whole-hub Z-Wave blackout to update one bathroom plug; force only when attended.

Never fire-and-forget across marginal devices. Flash strong-signal devices; leave floor-RSSI ones on their current firmware.

Recovery and verification

  • Reboot clears the hang: GET /hub/advanced/getManagementTokenGET /management/reboot?token=<token> (~2–3 min; zwaveJS re-interviews every node; confirm a fresh systemStart in /hub/eventsJson). On the automation hub a reboot is a ~3-min blackout, so prevention (the guardrails) beats recovery here.
  • Nothing bricks from a hang — after recovery all nodes read nodeState OK; a stalled node sometimes even completes to target once the reboot frees the queue.
  • Verify each node against its target: the hub caches the old version in device.data.firmwareVersion until the post-reboot re-interview, so poll /hub/zwave/deviceFirmware/details?nodeId=Ntargets[0].version until it flips. Report per device — updated / already-current / skipped-weak / failed — and name any failure with its current version (on old firmware, not bricked, retryable).