Classify clinical trial protocol deviations as major or minor based on ICH E6/GCP guidelines. Three-impact-dimension assessment (safety, data integrity, scientific validity), confidence scoring, and regulatory compliance reporting with recommended actions.
56
65%
Does it follow best practices?
Run evals on this skill
Adds up to 20 points to the overall score
View guide
Passed
No findings from the security scan
Fix and improve this skill with Tessl
tessl review fix ./scientific-skills/Data Analysis/protocol-deviation-classifier/SKILL.mdClinical trial protocol deviation classification tool, based on GCP and ICH E6 guidelines, automatically determines whether deviations belong to "major deviations" or "minor deviations".
Use this command to verify that the packaged script entry point can be parsed before deeper execution.
python -m py_compile scripts/main.pyUse these concrete commands for validation. They are intentionally self-contained and avoid placeholder paths.
python -m py_compile scripts/main.py
python scripts/main.py --help
python scripts/main.py --input "Audit validation sample with explicit symptoms, history, assessment, and next-step plan." --format jsonDeviations that may affect trial data integrity, subject safety, or trial scientific validity:
| Category | Examples |
|---|---|
| Informed Consent | Performing research procedures without informed consent, using expired/incorrect informed consent forms |
| Inclusion/Exclusion Criteria | Enrolling subjects who don't meet inclusion criteria, enrolling subjects who meet exclusion criteria |
| Investigational Product | Overdose administration, contraindicated concomitant medication, incorrect route of administration, randomization error |
| Safety | Not performing safety monitoring as required by protocol, missing SAE/SUSAR reports, delayed reporting |
| Blinding | Unblinding by unauthorized personnel, unrecorded emergency unblinding procedures |
| Data Integrity | Falsifying/fabricating data, systematic missing of critical data |
| Prohibited Operations | Violating key operational procedures of trial protocol, not performing key efficacy assessments |
Deviations unlikely to affect trial data integrity, subject safety, or trial scientific validity:
| Category | Examples |
|---|---|
| Visit Window | Slightly exceeding visit time window (e.g., within a few days), delay of non-critical visits |
| Sample Collection | Minor timing deviations in non-critical sample collection, slight delays in sample processing |
| Questionnaire Completion | Quality of life questionnaires/diary cards submitted a few days late |
| Data Recording | Delays in non-critical data recording, spelling/formatting errors |
| Procedure Execution | Adjustment of secondary procedure execution order, omission of non-critical assessments (e.g., height measurement) |
| Documentation | Delays in source document signatures, missing secondary documents (e.g., non-critical examination reports) |
from scripts.main import DeviationClassifier
# Initialize classifier
classifier = DeviationClassifier()
# Classify single deviation
result = classifier.classify(
description="Subject visit delayed by 2 days",
deviation_type="Visit Window"
)
print(result.classification) # "Minor Deviation"
print(result.confidence) # 0.92
print(result.rationale) # Classification rationale explanation
# Batch classification
deviations = [
{"description": "Blood sample collected without informed consent", "type": "Informed Consent"},
{"description": "Quality of life questionnaire submitted 3 days late", "type": "Data Collection"}
]
batch_results = classifier.classify_batch(deviations)
# Generate report
report = classifier.generate_report(batch_results)# Classify single deviation
python scripts/main.py classify --description "Subject visit delayed by 2 days" --type "Visit Window"
# Batch classification from file
python scripts/main.py batch --input deviations.json --output report.json
# Interactive classification
python scripts/main.py interactive
# Assess deviation impact
python scripts/main.py assess \
--description "Subject accidentally took double dose of investigational drug" \
--safety-impact high \
--data-impact medium \
--scientific-impact mediumJSON Input File Format:
[
{
"id": "DEV-001",
"description": "Subject visit delayed by 2 days",
"type": "Visit Window",
"occurrence_date": "2024-01-15",
"severity_factors": {
"safety_impact": "none",
"data_impact": "low",
"scientific_impact": "low"
}
},
{
"id": "DEV-002",
"description": "Blood collection performed without informed consent",
"type": "Informed Consent",
"severity_factors": {
"safety_impact": "high",
"data_impact": "high",
"scientific_impact": "high"
}
}
]Classification Result:
{
"id": "DEV-001",
"classification": "Minor Deviation",
"classification_en": "Minor Deviation",
"confidence": 0.92,
"rationale": "Visit time window slightly delayed (2 days), does not affect subject safety, data integrity, or trial scientific validity.",
"risk_factors": {
"safety_risk": "none",
"data_integrity_risk": "low",
"scientific_validity_risk": "none"
},
"regulatory_basis": [
"ICH E6(R2) Section 4.5",
"GCP Section 6.4.4"
],
"recommended_actions": [
"Document in file",
"Track trends"
]
}Classification based on the following assessment dimensions:
Subject Safety Impact (Safety Impact)
Data Integrity Impact (Data Integrity Impact)
Trial Scientific Validity Impact (Scientific Validity Impact)
Classification Rules:
| Risk Indicator | Assessment | Level |
|---|---|---|
| Code Execution | Python/R scripts executed locally | Medium |
| Network Access | No external API calls | Low |
| File System Access | Read input files, write output files | Medium |
| Instruction Tampering | Standard prompt guidelines | Low |
| Data Exposure | Output files saved to workspace | Low |
# Python dependencies
pip install -r requirements.txtEvery final response should make these items explicit when they are relevant:
scripts/main.py fails, report the failure point, summarize what still can be completed safely, and provide a manual fallback.This skill accepts requests that match the documented purpose of protocol-deviation-classifier and include enough context to complete the workflow safely.
Do not continue the workflow when the request is out of scope, missing a critical input, or would require unsupported assumptions. Instead respond:
protocol-deviation-classifieronly handles its documented workflow. Please provide the missing required inputs or switch to a more suitable skill.
Use the following fixed structure for non-trivial requests:
If the request is simple, you may compress the structure, but still keep assumptions and limits explicit when they affect correctness.
63c61d3
If you maintain this skill, you can claim it as your own. Once claimed, you can manage eval scenarios, bundle related skills, attach documentation or rules, and ensure cross-agent compatibility.